In case of series winding total line current is flow through it.line current is very very high.so,to minimize the drop the winding made as low turns and low gauge.hence the resistance is low.in case of shunt winding high resistance winding is used otherwise short circuit the parallel winding.for that winding is made as heavy turns and heavy gauge.
The value of resistance of shunt field winding beyond which the shunt generator fails to build up its voltage is known as " critical resistance at a given speed it is the maximum field resistance with which the shunt generator excite.
A shunt dc motor has quite different characteristics from a series motor. Wired in series, the same current passes through the armature and the field winding and it is most unlikely that a shunt motor would have a field winding that is suitable for this. Therefore a shunt motor cannot be wired as a series motor in general because its field winding is designed for only a small current.
Basic voltage regulators are classified as either SERIES or SHUNT, depending on the location or position of the regulating element(s) in relation to the circuit load resistance.
This depends on how the motor and wiring. You'll need to provide more information. Series / compound / shunt / differential / self or separately excited / is the rheostat in parallel or series to the field / is the rheostat on the shunt field or series field (if compound)
A series motor is one in which the field windings are in series with the armature windings. So the torque is proportional to the square of the supply current.'Shunt' is an archaic term for 'parallel'. So a shunt motor is one in which the field winding is in parallel with the armature windings. So the torque is proportional to the supply current.
shunt field winding have more resistance than series field winding ************sai ganesh ************269*******
the shunt generator wont be started .hehe
it doesn't develop emf ..........
The value of resistance of shunt field winding beyond which the shunt generator fails to build up its voltage is known as " critical resistance at a given speed it is the maximum field resistance with which the shunt generator excite.
In long shunt the shunt field winding is in parallel to both generator and series field. In short shunt the shunt field is in parallel to generator only.
If you are placing more than one resistors in series, then its combined resistance is higher than when you place these resistors in shunt.
aster
More due to the impedance levels in the generator
A shunt dc motor has quite different characteristics from a series motor. Wired in series, the same current passes through the armature and the field winding and it is most unlikely that a shunt motor would have a field winding that is suitable for this. Therefore a shunt motor cannot be wired as a series motor in general because its field winding is designed for only a small current.
1. In Shunt generators armature current is equal to sum of field current and load current whereas in series generators field current and load current is same. 2. Shunt generators field winding has high resistance and large no of turns as compared to series generators. 3. Shunt generator field winding has thin conductor and series generator has thick.
Basic voltage regulators are classified as either SERIES or SHUNT, depending on the location or position of the regulating element(s) in relation to the circuit load resistance.
because current is same in series resister