answersLogoWhite

0

A shorted coil or shorted coils in the rotor will cause arcing at the commutator. It should also be noted that if the brushes are damaged badly enough where they make contact with the commutator, this can cause arcing. Oh, and let's not forget that a stuck brush or brush spring will prevent a brush from making proper contact with the commutator. Arcing can result from that, too.

What else can I help you with?

Continue Learning about Natural Sciences

What part of an electric motor repels the poles of an permanent magnets?

commutator


What will most likely cause arcing at a switch contact?

Arcing at a switch contact is most likely caused by loose or corroded connections, excessive current passing through the switch, or a defective switch mechanism. These conditions can create an unstable electrical path, leading to arcing between the switch contacts.


Why do wall outlets arc and burn?

because 1) you are plugging them in under load 2) they no longer fit properly, so when a load is applied the current path is not always constant (cord wiggling from movement) so the electricity has to jump (arc). +++ Persistent arcing (not "arching"!) will damage them! If the problem is as described in answer 2)... replace it!


Is copper harder than mica in a commutator?

Yes, copper is generally harder than mica. In a commutator, copper serves as the conductive material, while mica is used as an insulating layer. Copper's hardness allows it to effectively conduct electricity and withstand wear, while mica's softness and flexibility allow it to provide insulation without cracking. Overall, the combination of these materials optimizes the performance of the commutator in electrical applications.


What could be the cause of arcing between the buss bar and a breaker?

Arcing between the bus bar and a breaker could be caused by loose connections, excessive load on the circuit, corrosion or physical damage to the components, or poor installation. It is important to investigate and address the root cause promptly to prevent damage and ensure safety.

Related Questions

Name two reasons for arcing at the commutator?

1) When the armature is open. 2) When the Field is open. 3) Commutator segments are internally short.


What are the two reasons for arcing at the commutator?

A shorted coil or shorted coils in the rotor will cause arcing at the commutator. It should also be noted that if the brushes are damaged badly enough where they make contact with the commutator, this can cause arcing. Oh, and let's not forget that a stuck brush or brush spring will prevent a brush from making proper contact with the commutator. Arcing can result from that, too.


What is use of commutator?

The commutator is used to convert the AC to DC


What is the use of Commutator?

The commutator is used to convert the AC to DC


Explain the necessity and principles of commutator in Dc generator?

what is necessity of commutator in DC generator


Why commutator are not used in ac motors?

Because, the commutator segments are used for converting AC to DC.


What is the definition of commutator?

A commutator is an electrical switch that periodically reverses the current direction in an electric motor or electrical generator. A commutator is a common feature of direct current rotating machines.


How does the commutator reverse the current in a motor?

Commutator is a split ring which reverses the current .when the commutator turns around due to magnetic force and because of it even the current gets reversed


What causes sparking?

It depends on the type of sparking/arcing. If you mean in a DC or series-wound motor, it is caused by the making and breaking of the commutator segments against the motor brushes.If you mean under a car, then it could mean that the muffler is dragging the ground.If you mean in a CRT television, then it is likely problems with the flyback transformer.


Which type of motor uses a commutator?

Commutator is a device in a motor through which supply is fed.


Is a commutator the rotating element of a motor?

The commutator is part of the armature on a DC motor and this assembly is the rotating element of a motor.


How commutator converts AC to DC?

There is no conversion of AC to DC a commutator is the key to creating straight DC voltage. "The commutator rotates with the loop of wire just as the slip rings do with the rotor of an AC generator. Each half of the commutator ring is called a commutator segment and is insulated from the other half. Each end of the rotating loop of wire is connected to a commutator segment. Two carbon brushes connected to the outside circuit rest against the rotating commutator. One brush conducts the current out of the generator, and the other brush feeds it in. The commutator is designed so that, no matter how the current in the loop alternates, the commutator segment containing the outward-going current is always against the "out" brush at the proper time. The armature in a large DC generator has many coils of wire and commutator segments. Because of the commutator, engineers have found it necessary to have the armature serve as the rotor(the rotating part of an apparatus) and the field structure as the stator (a stationary portion enclosing rotating parts). Which is the inverse of an AC Generator."