What determines the magnitude and polarity of the counter-emf in a dc motor?
the magnitude is decided by the amount of flux, number of conductors, speed of the motor and the type of the winding used.
the polarity is decided by the direction of rotation of the motor and the direction of armature current flowing in the motor.
Work it out for yourself. The equation is: R = resistivity x (length/area). Incidentally, 1.55 m2 is an enormous area, if you are describing a conductor!!!! And 2.8 doesn't appear to represent a practical value of resistivity.
That is how inductance works. The rise is needed to charge the primary. When the field collapses, that is when the current is induced in the secondary winding(s).
Which motor run in both direction?
Trick question: all motors do if you invert the polarity of input.
CommentNot a trick question! In the case of d.c. motors, for example, you have to reverse the polarity to either the field or the armature -not to both. If you reverse it to both, it makes no difference to the direction of rotation! For a three-phase induction motor, you must interchange any two line conductors.
Is there any windage loss in transformer?
In this context, 'wind', in 'windage', is pronounced as 'wind' -as in 'breeze' or 'gale'. 'Windage means air-resistance, and this only applies to rotating machines, such as generators and motors, whose rotors have to overcome air-resistance (windage) as they rotate. As transformers have no moving parts, they are NOT subject to windage loss!
Is universal motor type of inductin motor?
No,look at the connection diagram for Universal motor. The Field and the armature windings are connected in series. But, in induction motor, the rotor end terminals are sorted by a kind of rings.That is rotor is apart from the supply.
Is a series inductive reactor a switchgear?
'Switchgear' is a generic term for all switching devices, such as circuit breakers, isolators, air-break links, etc. A reactor is simply a coil so, no, it is not classified as being switchgear.
Why power factor expressed in cosine angle?
The vector-relationship between apparent power, true power, and reactive power is represented by a right-angled triangle, whose hypotenuse represents apparent power and whose adjacent represents true power. Since power factor is defined as 'the ratio of true power to apparent power', you will find that this ratio corresponds to the cosine of the angle between them.
case study
Formula to calculate min insulation resistance?
insulation resistance = (2 * operating voltage +1000V)
at operating temperature
if you define what you mean by minimum insulation resistance maybe i could help
132,000V on the towers is usually happy with 6' of air
some insulation is far better than air
dry air 500v/mill
thermoplastics 6000v/mill
your power drill has 1/8" - 1/4" of plastic on the cord
and perhaps .001" on the wire in the coils
the cord gets rougher handling
anything practical insulation resistance (2 * operating voltage +1000V)
witch means a 1500Vdc megger is ok for 120V appliances
should be safe to handle if its more than 10megohms
the 1500V will bridge any pinholes or airgaps
NEVER use a vom the 9v battery wont find a pinhole or an air gap
ceramic on heaters and toasters has a way of letting metals diffuse in it lowering the resistance over time also it usually lowers with temperature
so the resistance reading will be a lot lower while its hot
What color are the directional capacitors?
They can be many different colors, shapes and sizes. To identify whether a capacitor is directional or not, you must look at the markings on it - if it is directional, it will have a little +, and possibly a - to denote directionality (some only have the + I believe due to size).
In general, electrolytic capacitors are normally directionalized. These are the capacitors that resemble batteries in shape, and usually have an 'X' on the bottom (this creates a weak point in the casing; if the capacitor overheats for whatever reason - overvoltaging, or revers polarizing- the 'X' will fail first).
Shading ring in magnet of electrical contactor?
Best guess?
A shading ring aborbs energy from a changing magnetic field, so I'm guessing it will slow the opening and/or closing time.
Try a web search:
electrical contactor shading ring
What is the difference between characteristic impedance and intrinsic impedance?
I believe intrinsic impedance is more tied to the medium, thus is defined in terms of magnetic and electric permeability and electrical conductivity, while characteristic impedance is a "wider" look at the impedance.
For example, you can calculate the intrinsic impedance of a 18 awg copper wire, or air, or a vacuum. If you wanted to use coax cable with an 18 awg core, you would be looking at the characteristic impedance, not the intrinsic impedance of the copper that will be carrying the waveform.
Applications of variable DC power supply?
Variable dc supply is applicable in loads that are variable.
What are the factors that create an imbalance of power within a culture?
The imbalance of one goup over another (more of one then the other).
A Vacuum is the absence of air. So no, there is no air in a vacuum.
Soft low melting solid which is a good conductor of heat?
The metal lead. Solid at room temps, low melting point, good conductor of heat and electricity.
Why Capacitor bank should be switched off when DG is in operation?
When generation kicks on, it can cause system voltage to rise, fall, or stay the same. Capacitors banks are used to help boost system voltage. Inductor banks are used to pull system voltage down.
In many situations, capacitor banks may be required to kick ON when generation kicks on - some wind turbines "suck in VARS", or act like inductors while pushing out power. This causes system voltage to sink, and must be counteracted using capacitors.
In your situation the distributed generation may be causing unacceptable voltage increases with the capacitor bank online.
Draw the equivalent circuit of UJT?
we can draw an equivalent circuit for UJT USING a DIODE and two resistors.draw a diode in emitter lead ..draw the two resistors in series.As rb1 in base 1 lead ..and rb2 in base 2 lead ..draw rb1 as variable resistor.And put a voltage to the ujt in order to get a positive voltage in base two lead.
What is the formula of ohms law?
Ohm's law describes the relationship between ideal resistance, voltage, and current. Voltage is resistance times current. It is a useful rule of thumb for non-technical people and not an absolute law.
Another Answer
Ohm's Law is probably the most misunderstood so-called 'law' in electrical engineering. What it states, in essence, is that 'the ratio of voltage to current is constant for variations in voltage'. Unfortunately, and this is where the misunderstanding comes in, is that Ohm's Law applies to hardly any load! It doesn't apply to most conductors, and it doesn't apply to most electronic components such as diodes, etc. For Ohm's Law to apply, a graph of current against voltage, for variations in voltage, MUST produce a straight line -and this is hardly ever the case! For example, if we tried to draw this graph for, say, tungsten, we'd end up with a curve -which means Ohm's Law doesn't apply to tungsten!
It's also incorrect to say that Ohm's Law is represented by the equation, R = V/I. This equation is derived from the definition of the ohm, and NOT from Ohm's Law.
To summarise, Ohm's 'Law' is NOT a law at all! To be a 'law', it must be universal (i.e. must apply in every case), and that is not the case with Ohm's 'Law'.
How do you connect oscilloscope probe to 120 v outlet to view voltage waveform?
You do this carefully. It might be better to use a plug on a wire where the other end is bare (aptly named suicide cables), connect the oscilloscope, first to the bare wire (firmly), then plug into the wall. This will prevent potential arcing to your probes, which can be relatively expensive depending on your o-scope. I believe last time I looked, they can run upwards of $100 for a good one, so you don't want to ruin them. Make sure hands and equipment are dry.
An even BETTER way is to NOT look at the 120 volts directly, but through a step down transformer; this will keep the voltage at a safer level. If you do this, it's a good idea to fuse the primary connection so you aren't banking on your home breakers. Besides, why do you need to look at the 120v? On o-scope isn't going to show much, other than a nice pretty 60 or 50 Hz signal (harmonic content, flicker, etc. are very small, and if large will be very short lived - thus hard to catch).
What is the Function of NO and NC contacts?
Normally open and normally closed contacts are used in controls circuitry. They serve many functions.
The field winding on a generator is the winding that is electrified to create an electromagnet; it is generally the winding found on the rotor (the rotating part of the generator).