What is a phase discriminator?

A Phase discriminator allows the user to shift in time or 'phase' into another dimension. It shifts the user into another dimensional phase which can be a fraction of a second off from our own, which renders the user invisible to those in the normal unshifted time frame.

What is supply voltage in 45nm?

0.8-1.2V Depends on manufacturer and technology options.

How can you use a 3 phase capacitor as a single phase capacitor?

Just use any two of the three terminals that are available, this will give you a single phase capacitor.

What is positive isolation in plant?

Positive isolation is a method of Isolation where there is Zero potential of energy at the workplace.

  • All Hazardous Energy has been identified
  • All are isolated at the source
  • Residual Energy has been eliminated.

eg. Electrically Isolated at the Transformer, earth applied, and fuses removed.

eg. Mechanically Isolated at the Pump, valve closed, blanked-off. Line drained, purged, etc

What is mA symbol?

While one might expect a latin symbol for amperes or milliamps, A and mA are the accepted symbols for these.

How does electromagnetic induction works?

Electromagnetic induction is the production of an electromotive force across a conductor when it is exposed to a varying magnetic field. Basically it works because of electricity.

100w bulb and 60w bulb connected in parallel to 220v which will glow brightly?

Total supply voltage = 220v

rated power of first lamp= 100 watt

so current though it, I=p/v

I=100/220=.45 amps

Resistance offered by first lamp=220/.45= 488 ohms( i avoid fractions)

..............................................................

rated power of second lamp=60 watts

voltage is same, so current through it = 60/220=.27 amps

resistance of second lamp = 220/.27=814 ohms( i avoid fractions)

.........................................................................

power drawn by first lamp =I12 R

=(.45)2 * 488 =98.82(=100)

power drawn by second lamp =I22 R

=(.27)2 * 814 =59(=60)

...................................................................................

SO 100 WATT BULB WILL GROW BRIGHTER AS IT HAS MORE POWER

What are No Load And Locked Rotor tests on a three phase induction motor?

Doing a No Load test of a 3-phase induction motor involves the measuring of current, voltage, torque etc with no load on the rotor shaft, meaning that it is free to turn but is not driving anything else.

Similarly a Locked Rotor test involves the measuring of current, voltage, torque etc with the rotor shaft "locked" i.e. prevented from turning, which is the worst loading condition the motor would ever have to contend with.

Experimental error caused by instrumental limitations?

Error caused by instrumental limitations is actually called systematic error, not experimental error.

When use undervoltage release?

Under voltage protection (release?) is used in industry. If there was a power failure and a piece of equipment was running when the failure occurred for safety reasons the machinery should not start up on its own when the power returns back on. With under voltage protection the operator restarts the machinery after checking that there is no danger to anyone and the machine is clear to start. To obtain this safety feature an electrical contactor is used in conjunction with remote stop - start buttons located at the machine the operator is working.

What is a tap changer?

A tap changer is a device on the outside of transformers to allow the changing of the primary windings to except different primary voltages. A common one is 7200 - 14400 volts. Look up at the transformers on the poles to your house and you will be able to see this handle with the voltages stamped on the case and the handle in one of the positions. This allows for the transformer to be used on two different primary voltages. What this cuts down on is storage of single primary voltage transformers.

Comment

Tap changers are normally incorporated into the high-voltage, rather than the primary, winding of a transformer.

Difference between 89s51 and 89s52?

89s51 and 89s52 both are same version of 8051 microcontroller

What is quadrature axis reactance?

If the stator winding of a synchronized machine, which consists of many coils that are basically connected as a series

circuit, is not connected to a load then the resulting emf from all the coils is the open circuit emf of

the phase winding. Closing the circuit on to a load causes a steady state current to flow in the stator

coils. Each coil creates a flux and their total flux opposes the field flux from the rotor. The resulting

flux in the air gap is reduced. The emf corresponding to the air-gap flux drives the stator current

through the leakage reactance and conductor resistance of the stator coils. The voltage dropped across

this winding impedance is small in relation to the air-gap voltage. Deducting this voltage drop from

the air-gap voltage gives the terminal voltage of the loaded generator. In the circumstance described

thus far the reduction in air-gap flux is called armature reaction and the resulting flux is much smaller

than its value when the stator is open circuit. Restoring air gap and terminal voltage requires the

field current to be increased, which is the necessary function of the automatic voltage regulator and

the exciter.

When the rotor pole axis coincides with the axis of the stator coils the magnetic circuit

seen by the stator has minimum reluctance. The reactance corresponding to the armature reaction

in this rotor position is called the 'direct axis synchronous reactance Xsd '. If the stator winding

leakage reactance, Xa, is deducted from Xsd the resulting reactance is called the 'direct axis

reactance Xd '.

A similar situation occurs when the rotor pole axis is at right angles to the axis of the stator

coils. Here the magnetic reluctance is at its maximum value due to the widest part of the air gap facing

the stator coils. The complete reactance in this position is called the 'quadrature axis synchronous

reactance Xsq '. Deducting Xa results in the 'quadrature axis reactance Xq '.

Does the impedance of a parallel RLC circuit equal to the value of the resistor?

No. You have to consider the inductor and the capacitor.

Impedance of RLC circuit is equal to to the Value of Resistor Only AND Only on Resonate frequency.

otherwise u have to cnsider resistance inductance and capacitance together in series.

What is commutation in DC machines?

It is the process of conversion of generated ac voltage into the armature of a dc generator to dc voltage at the terminal of the dc generator by use of pair of brushes and commutator.

OR It is the process of conversion of given dc voltage at the terminal of the dc motor to ac voltage in the armature windings in a dc motor by use of pair of brushes and commutator.