What is a Class A circuit breaker?
A Class "A" Circuit breaker is a Ground Fault Interrupt (GFI or GFCI) breaker .
"Class A" marking -- A "Class A" ground-fault device is intended to protect people. The Class A marking indicates that the trip threshold of the GFCI is between 4 mA and 6 mA. This marking may be in any location except the back.
What is the power of a parallel circuit with a resistance of 1000 ohms and acurrent of 0.03 A?
The power will be the product of the square of the current and the resistance of the load. The fact that the circuit is a parallel circuit is irrelevant to this question.
P = I2R = 0.032 x 1000 =0.9 W
What are the types of electrical earthing with respect to Electrodes?
Electrical earthing is classified into many types as
Neutral earthing
Body earthing
Pipe earthing
Plate earthing
Chemical earthing
Ground Compound Earthing
What is the difference between gg fuse and gl fuse?
gL is the old designation for a general purpose fuse link--gG is the new name for that designation. Other than the name there appears to be no difference.
Design OF A fire fighting system for electrical control building?
we have to distinguish between firefighting and fire alarm system. fire fighting is mechanical work (either sprinkler system or Foam or CO2 or FM200) and there is fire alarm or detection system this is an electrical thing that includes ( detectors an fire alarm system) for electrical control building we use FM200.
What are the 5 parts of a Volt Ohm Meter?
Test Prod Scale meter Zero corrector Zero Ohms adjust Scale selector
Anderson's bridge used to measure self inductance?
we can find the value of inductance varying two varient resistance r & R by stoping the voic of beep in anderson's bridge
then
L=CR(Q+2r)
here C & Q are fixed capicitance & resistance in bridge..........
What do fuses in the fuse box in C 320 boot protect and what are their ratings?
diagram for the fuse box in the trunk of a 1995 c280
Is a capacitor a device specifically designed to measure currents?
No, a capacitor is a device that resists the change in electrical potential. It will take and hold a charge based on the value of the capacitor. It's most commonly used to "smooth" direct current or to pass a signal through a wire while passing very little current. There are some interesting circuits produced using capacitors, especially since the capacitors have so many unique properties.
either one could. it depends witch one you unscrew first.
How accurate are the readings of a megger test?
While using megger we only have to see whether resistance breaksdown at the upper value mentioned. Since megger generates high voltage we can check whether breakdown takes place or not.Megger has a range from o to infinity.So it is not possible to find accurate resistance,hence it is used as an insulation tester
What is the maximum voltage on the secondary side of the transformer?
Transformers come in very many varieties and voltages. Transformers have ratings regarding the electrical power that they are connected to. The most important ratings are voltage, power and current. In general the insulation level and number of windings in the secondary and primary determine the maximum rated voltage, and the size of the magnetic wire that makes up the windings, and mass of the iron core, determines the rated power and rated current.
It is the insulation level therefore, that determines the maximum, safe voltage that can occur on both the secondary side and the primary side. The turns ratio between the primary and secondary coils of the transformer determines the secondary voltage with respect to the primary voltage. If the primary coil has 1000 turns, and the secondary coil has 100 turns, the transformer turns ratio (usually designated by the letter "a") is 100 / 1000 = 0.1. If a = 0.1, then if 1000 volts are applied across the primary coil, ideally, 100 volts will be measured across the secondary.
Transformers have been manufactured with secondary voltage ratings in the range of millivolts, to 1,000,000 volts.
Compare kirchhoff's voltage law to ohm's law?
Kirchoff's voltage law states that the sum of the signed voltage rises in a series circuit adds up to zero. A consequence of this is that the voltages across elements in a parallel circuit are equal to each other.
Ohm's law states that voltage is equal to resistance times current.
The two laws can not be compared, because they talk about different things. They are, however, tools that can be used together, along with other laws such as Kirchoff's current law, and Norton and Thevanin equivalents, to perform circuit analysis.
Another AnswerThe simple answer is that Kirchhoff's Voltage and Current Laws are universal, and apply under all circumstances, whereas Ohm's Law is not really a 'law' at all! There are very few circumstances in which Ohm's Law applies and, in my opinion at least, should no longer be taught.When a light bulb is rated for 3.2 V it means that it is the maximum operating voltage to be applied to the bulb.
What is diode peak current in 12 volt power supply?
A: Diodes peaks current can exceed the forward steady sate current by a big factor for a short time without destroying itself. It will destroy itself if the power dissipation is exceeded. The answer to your question is the peak voltage has absolutely nothing to do with a 12 volts power supply or any other voltage power supply it has to do with the diode itself
Where is the knowledge of dielectric strength helpful?
One field in which this is helpful is in the manufacture of insulating materials. Dielectric strength determines the strongest electric field an insulator can withstand before it fails. For example, if the insulation around a wire melts or breaks, the insulator's dielectric strength is compromised.
What is maximum demand indicator?
An electricity board will be fixed some amount of load for consumer (industry or commercial) as per consumers requirement.That is maximum load or maximum demand
AnswerA 'maximum demand indicator' (also called a 'thermal demand indicator') is a thermally-operated measuring instrument which indicates the maximum current supplied by a distribution transformer, from which that transformer's actual (rather than anticipated) maximum load can be determined. A distribution transformer is sized based on an anticipated load, resulting from an analysis of the loads to be supplied (taking into account after-diversity maximum demand), this instrument allows the actual maximum load to be compared with that calculated load, and this value should be less if the original analysis was performed correctly.
What is a common mode amplifier?
I'm not sure there is such a thing as a "common mode amplifier". The common mode rejection ratio (CMRR) of a differential amplifier is very high, and is defined as the ratio of the differential amplification divided by the common mode amplification. The common mode amplification is what you get when both inputs are tied to the same signal. Ideally, this amplification will be zero, but in reality it ends up being some very small amount for well designed amplifiers.
This is a beneficial trait for audio equipment which use a positive, negative, and neutral connection (balanced cables, such as microphones). Noise signals will naturally couple to these cables. The assumption is these noise signals will couple nearly identically to both the positive and negative signal wires, so when applied to the amplifier, this common mode signal will not be amplified, while the desired signal (which is created so that the positive and negative signals are opposites) is amplified.
Can a foot mounted motor be used as a flange mounted motor What will be the effect?
Trouble is to get it mounted right. It'd be very rare to find an assembly spot set up to accept both flange mount and foot mount. But assuming the motor spec is the same (power, RPM, etc) it'll work just find assuming you get the alignment right.
Does copper loose electrical conductivities when heated?
no it does not, because it conducts heat and electricity
AnswerThe word you are looking for is 'lose', not 'loose'! And the answer is yes. The resistivity of copper increases with temperature, so raising its temperature will cause its resistance to rise or, if you prefer, its conductivity to fall.
Can the 2.2 microfared 250V capacitor be charged with 12V dc source?
Yes. The 250 voltage is a not-to-exceed rating.