Why is circuit current reduced when a capacitors added to the circuit?

In the case of an a.c. circuit, capacitors oppose current because of their capactive reactance, expressed in ohms. Capacitive reactance is inversely-proportional to the capacitance of the capactor and to the frequency of the supply. So, adding a capacitor is series with an existing load will reduce the load current. On the other hand, adding a capacitor in parallel with an existing load will decrease the load current.

Will a circuit breaker function properly if it is back fed?

Yes. The circuit breaker "does not care" which direction the current comes from. It is capable of protecting the circuit in any case.

Will using clip-on iron ferrites on cables remove mains induced transformer hum from a mixer?

Mixers are complex pieces of equipment and mains hum can be induced from a variety of sources. In many cases, it is due to earth loops or other earth issues. In some cases, a power supply may give rise to noise on the outputs.

Ferrite cores clipped to a cable are unlikely to make any difference to the hum. Get the connections right and the hum will probably disappear.

Why only electrolytic capacitors are used for filter dc?

high capacitance better filtering, electrolytics have high capacitance per volume. however electrolytic have some parasitic inductance, so many small ceramic capacitors are distributed on cards near ICs as a final "cleanup" filter and switching noise suppressor.

I need a 120V 208V 3 phase What size of 3 phase transformer do you need?

The sizing of transformers is based on an accumulation of all of the loads that will be connected to it. Add up all of your loads and possible loads in the future and then tell your installer the figures and they will use these to calculate the size of the transformer that is needed.

How much current a relay coil can withstand?

There are basically two parts to a relay. The control voltage side when energized passes a current through a coil that activates a solenoid and opens or closes a switch. This is typically a small current. The current in the switch should be rated on the device and is usually quite a bit higher than the control current.

What is meant by VCV cable?

Vertical Continuous Vulcanization

it is the name of the process by which a MV or HV cable is made up.

What is the difference between an inductive low pass filter and a capacitive low pass filter?

Where you are measuring. A simple filter will be two elements - a capacitor or inductor and a resistor. A capacitor will tend to "trap" low frequencies. In the case of a lowpass filter made of a capacitor and resistor, the output voltage will be measured across the capacitor. Inductors are the opposite, so the output would be across the resistor.

What part of the ohms scale of a meter are the most accurate resistance measurements made?

It really depends on what you are trying to get the resistance of. A piece of copper wire 30 feet long will only have a resistance of few ohms. A person can have a resistance of several million ohms. Making sure that your meter's leads are in good contact with whatever you are measuring is the best way to get an accurate reading.

60 ohm and 40 ohm and 20 ohm resistors are all 3 connected in series across a 120VAC source what is the total voltage across 40 ohms resistance?

Total resistance is 120 ohms. The 120VAC will be split evenly over this 120 ohm load, so every ohm of resistance gets a volt. So there will be a 40 volt drop across the 40 ohm resistor.

Why is electricity is transported in high voltage but not in current?

This is done in order to minimize power losses in the power distribution network due to the resistance of the transmitting cables. It should be noted that for a given cable resistance, voltage drop, and thus power dissipated in the cable and not available to use, is directly related to the current flow through the conductor.

According to the Power Law: P = I2 ×R, that is power (in this case, power lost) is equal to current squared times resistance. To deliver power, it takes amps and volts. If you raise the volts, you can reduce the amps and still get the same power. If you reduce the amps, you lower the losses. Did you notice the squared term in the formula? That means if you reduce the current to one-tenth of the original value, your losses go down to one one-hundredth of what they were.

This is a huge issue for the utilities. Every kW lost is one they cannot collect money for, yet they still have to pay for fuel to generate it, they have to size the generator bigger to supply it, and they have to size the transmission system to carry it. There are other good reasons too (see below), but minimizing line loss is the $main$ one. A few transmission systems have been designed at 1.2 million volts. The utilities would have billion-volt systems if they could figure out how to do it.

2nd Answer

A major reason is that, to carry the same amount of power, if the transmission voltage is made higher, then, even though a thinner cable has a higher resistance for a given length, the cables can be made thinner and lighter in weight.

Use of a higher transmission voltage saves a tremendous amount of money in many ways. For example for the expensive material used for the cables (often a steel multi-strand core wound with an outer skin of copper, aluminum, or similar good conducting wires) and for the weight and costs of construction and erection of the towers that carry the cables across the countryside.

To carry 400 kV (= 400 kilovolts = 400 thousand Volts) the steel towers have to be taller and the porcelain insulators have to be longer than they would have to be for cables carrying lower voltages but the cost of making the towers taller and the insulators longer is far less than the cost of the extra weight of the much thicker cables that would be needed to carry the same power at a lower voltage. *** (See Note below for more explanation)

There are many other costs which have to be reckoned when deciding what voltage to use for long-distance power distribution. For example the high cost of the massive power Transformers and big switching stations that have to be included in the power distribution network; the power that is lost from the cables - radiated to the surrounding air as heat - because of the electrical resistance of the materials from which the cables are made.

The above answer just gives a very simplified overview of the kinds of things a skilled power transmission engineer has to work with and calculate when designing a new power transmission network.

3rd Answer

Transmission and quantum of electricity can be considered analogous to hydraulics. Reckon voltage as pressure, the longer the distances, the higher the pressure required to pump. That is why for long distance transmission high pressure (voltage here) is required, failing which, the power will not reach the destined end. It will dissipate on the way. Reckon current as quantity which will be drawn from the pipeline (cables here) at the pressure/voltage required.

*** Note:

If we use the Electric Power Equation we can get an idea of what the descriptions given in the answers above really mean:

P = V × I or, in words:

P (power) = potential difference V (voltage) times current I (amperage)

So, using simple mathematics we can say that:

I = P / V or, in words:

Current I (amperage) = P (power) divided by potential difference V (voltage)

Now, as an example, if a small town needs to have a supply of power W of say 1 MW (= 1 megawatt = 1 million watts) to be delivered over cables from a power generation station:

Calculation A:

If the voltage V used for transmission through the cables is 1000 Volts then the current I in the cables would have to be:

P / V = 1,000,000 / 1,000 = 1,000 amps

which would require a very thick and heavy, and therefore very expensive, cable and associated support towers.

Calculation B:

If the voltage V used for transmission through the cables is 400 kV (= 400 kilovolts = 400,000 volts) then the current I in the cables would have to be:

P / V = 1,000,000 / 400,000 = 2.5 amps

which can be carried safely in a very much thinner, lighter and less expensive cable and support tower.

Line supports are mainly two types:

1. poles

Poles are classified as wood poles, concrete poles and steel/aluminum poles.

2. towers

Towers are classified as self supporting towers and stayed/guyed towers.

Self supporting towers are in two types: wide base and narrow base.

Stayed towers are classified as portal type and V-type.

What devices could be used on the output of a half wave rectifier?

The waveform from a half wave rectifier looks just as it is described by its name: half of a full sine wave. That will cause a pulsed or "ripple" effect in the output voltage and current that come out from the rectifier.

Whether that will cause a problem depends on the application you are using.

For instance, if it is a light bulb, it will appear to flicker at the frequency of the alternating current service that has been rectified, which can be very annoying!

If it is a device such as a charger for the battery of a digital camera or an electric shaver, the pulsed output current doesn't matter at all.

How is it possible to have a high current with a low voltage such as in a car battery if current equals Voltage divided by Reistance then shouldn't a low voltage produce a low current?

It's all relative. A battery has internal resistance. Batteries are not "ideal" voltage sources. If there is a "heavy" load on the battery (low resistance), the voltage you measure on the outside of the battery will be lower. A car battery is normally thought of as a 12 volt battery. When there is no load (disconnected) you can often measure in excess of 13 volts if it's fully charged. During normal cranking of the engine, the voltage can drop below 11 volts.

What is the common household electrical service is usually rated at phase?

The common household electrical service is usually rated as a single phase service. In North America there are a few 120/208 three phase services being put into larger homes.

Drop out voltage of a solid state relay?

Typically, when the coil voltage on a relay is decreased gradually, the relay "hold" will release at a certain voltage. This is usually defined as the Drop-out voltage (defined at some minimum value).

Now, in the case of latching relay, the Drop-out voltage is called the Reset voltage.

What is the difference in construction between power diode and simple diode?

Basically the semi-conductor junctions are a larger surface area and heat sinks are part of the design to dissipate heat.

What is standby output of generator?

The word "standby" is used in 2 ways.

1) A standby generator is essentially a spare power source for when the main one fails. Usually cuts in automatically.

2) Kubota J series (and others?) say eg Prime output is 10kVA, and Standby output is 11kVA. I presume this means you can get 11kVA, but not good for the engine.

How do TV and Radio stations remain on the air if transmission lines or power lines are down?

Many of them have their own emergency generators,

ready to take over if the commercial power fails.

Why does alternating current allow power transmission?

First of all, it's energy that's being transmitted, not power! Power merely tells us the rate at which energy is being transmitted.

Next, it's a complete misconception to think that energy is delivered by electrons which, then, return to the source to collect more energy -rather like a conveyor belt! Electrons move far too slowly for that to happen (an individual electron is unlikely to travel the length of a flashlight's filament before the battery runs down!). It's far more likely that energy is delivered in the space around (rather than through) the supply wires due to a combination of the electric and magnetic fields, called the 'Poynting Field' (check this out on the internet).

Finally, if we think of 'positive' power as the rate at which energy is being transmitted in the 'forward' direction (i.e. from the source to the user) then, during the negative half-cycles of a.c. current and voltage, the product (P =EI) is still positive. So it matters not whether it is being 'delivered' by d.c. or a.c.