What is a Compound Wound Traction Motor?
It is a Direct Current Motor which is wound and creates a magnetic field when energized and does not use a permanent magnet. Jeff S.
7.2 A
Can you apply 230 v ac to kbpc2510?
we can apply 230v ac to kbpc2510
maximum peak voltage is 325v (for 230v)
and its blocking capacity is about 1000v
so we can use it
(I used for the same application)
V = 155*sin[120pi*t + a] where V is the voltage, t is the time in seconds and a is the phase shift.
Which is Most common insulation at high voltage?
The most common insulation material for HV use remains porcelain. Synthetic materials are fast replacing porcelain as the insulation material of choice.
How to control speed of dc motor using microprocessor 8085?
Here the DC motor is controlled by the
microprocessor (8085). The kit used
was dynalog 8085 kit.
The DC motor is very difficult to
control unlike the stepper motor,
which can be controlled by giving the
appropriate CONTROL WORD.
By knowing the DC motor theory we
know the different methods used to
control the motor, the most primitive
and the once upon a time the most
popularly method was WARDLEONARD
motor speed control, but
this had many disadvantage, so the
world of Electronics brought in the
thyristor control, which were very
flexible and can be employed to use
AC instead of DC cause they had a
inbuilt convertor. The thyristor-based
system is good but when used with Microprocessor based speed controller they are really
good. We have shown the block diagram, circuit diagram used by us to control a small
tape recorder sized motor
How do you calculate thickness of oxide in MOS Capacitor?
C0 = (K0*e0*Ag)/x0
C0: oxide capacitance
K0: 3.9
e0: 8.85x10^-14
x0: thickness of oxide
How does a soldering iron works?
An electric heating element heats the tip just above the melting temperature of the solder being used.
Kirchoff's current law states that the current at every point in a series circuit is the same. If the radio is drawing 200 mA, then so will the resistor.
Kirchoff's voltage law states that the sum of the signed voltage drops in a series circuit all add up to zero, or that the voltage across parallel elements is the same. If the battery is providing 12 V, and the radio is using 9 V, then the resistor must be using 3 V.
Ohm's law states that resistance is voltage divided by current. If the voltage across the resistor is 3 V, and the current is 200 mA, then the resistor must be 15 ohms.
A consequence of the definition of voltage, current, and power is that power (joules per second) is voltage (joules per coulomb) times current (coulombs per second). The power dissipated by the resistor must then be 600 mW, so it should be rated at least one watt.
If the current drawn by the radio is not constant, a better solution might be to place a reverse biased 3 V zener diode in series with the radio, instead of a resistor. This will ensure that the voltage drop is always 3 V. Power across the diode will still be about 600 mW, for the 200 mA case.
In a single phase 220 volt electric motor just measure one line. That already represents your line current. That line current is equal to your total current circulating in your motor.
Why is the field left energized during dynamic braking?
the field is left energized in order that the motor behave like a generator producing an magnetic field in the opposed direction of rotation
Can a 230 volt single phase watt hour meter be used to monitor 115 volt single phase?
Yes it would work pretty well but it might not meet its accuracy specification.
The transformer you describe is being used as a step-down transformer, and is classified as an electrical machine. The transformer could either be a mutual transformer, consisting of two, electrically-isolated coils, or an auto-transformer which uses a common coil between its primary and secondary circuits.
How do you change a 6 wire three phase motor to a 3 wire?
The six wire motor is probably a two speed or a dual voltage motor. Look on the underside of the motor's junction box. Here is where the wiring diagram of the motor is pasted. Look on the motor's name plate to see if it is a two speed motor. There will be two sets of amps and RPM and maybe voltages.
It could be that six terminals are brought out to terminal box so that it can be connected either in delta or star configuration. As stated above the name plate details would indicate the correct connection.
Which types of relay is use in power transformer?
A 'power transformer' is a category of transformer used within electricity transmission and primary distribution systems. Relays are widely used with power transformers to provide various types of protection that will act to disconnect the transformer in the event of a fault. Examples of these relays include Buchholz relays, earth-fault relays, and differential relays. Relays are also used to operate a power transformer's automatic tap-changing mechanism in order to compensate for changes in load.
If the device requires 2.28 watts at 4.5 volts, then its current draw is 0.507 amperes. (Watts = volts times amperes) If you want to drop 0.5 volts at 0.507 amperes, you need a resistance of 0.987 ohms. (Volts = amperes times resistance)
One solution is to put a 0.987 ohm resistor in series with the device. That resistor would need to handle 0.253 watts, so a half watt resistor would be minimum.
Problem is, this depends on constant power demand by the device. If the power goes up or down, probably down, then the voltage drop across the resistor will change.
Another problem is that the closest standard resistor value to 0.987 is 1 ohm, and that would deliver slightly less than 4.5 volts to the device.
Another solution would be to place a diode in series with the device. The diode would drop about 0.7 volts, giving the device about 4.3 volts. Of course, the diode would need to be rated for 0.507 amperes and one half watt, but the output voltage would be more stable.
A regulator is probably not going to work, because you don't have enough headroom between 5.0 volts and 4.5 volts to do it without a complex design.
Best solution: Get a 4.5 volt power pack.
Robot sensors detect different things and send different amounts of electricity to the Robot's controller board to tell their findings. Then the controller board uses these different amounts of electricity to interact with its surroundings.
Example:
Lets say you have a robot that is made to follow light. Lets say your robot has 3 light sensors. One in the front of your robot one on the right and one on the left side. The sensors will detect how much light is on the front, right, and left sides and send this data to the controller board. Then the controller board uses this data to tell the robot with direction to go.
Is banning motorized machines good to us?
It is good in the context that it will be reducing carbon emissions and maybe stopping global warming. It is bad in the way it will effect our economy and society. No motorised vehicles means no transporting of goods which means many people will go hungry.
Can you tap off a 3 phase 277volt ac light fixture to power a single phase 120 volt ac recptacle?
NO! The voltages available in the 3-phase system are 480 (if you wire phase to phase) and 277 (if you wire phase to neutral) Don't try it!
Is a ground fault protection for equipment required even if the neutral will not be used?
Yes, ground fault protection for equipment is requiredeven if the neutral will not be used.
However, the question implies that it might not be required if there is a neutral. That is not true. With two exceptions, ground fault protection is always required in the US, and it is probably required in other countries as well.
The exceptions are the use of an electric cooking range, and an electric clothes dryer. In those cases, the US NEC allows the neutral conductor to also be the ground fault conductor, except for the case where the range or dryer is in a mobile home. In the case of the mobile home, the ground fault conductor and the neutral conductor must be maintained separate and distinct all the way back to the distribution panel.
In every other case, including where local code overrides the US NEC's exceptions, it must be understood that ground fault protection (protective earth ground) is not the same as neutral, even though the neutral conductor is grounded.
What is open delta connection in three phase transformer?
When you see "Delta" it is a kind of winding used in transformers or motors Think of a triangle. Each leg of the triangle is a winding. Power is connected to each of the three points of the triangle.
For more information see the answers to the Related Questions shown below.
RFID size is normally determined by the size and configuration of the antenna, not the actual RFID integrated circuit.
Hitachi sells chips with low-performance internal antennas that are the size of a table salt crystal. Most RFID tags are between 20 and 100 mm in length/width and very thin.
What is a generator transfer switch used for?
A generator transfer switch is used to switch an electrical load between different sources such as grid power and a standby generator or between multiple generators to allow for maintenance of a generator in a set. These switches can be automatic, switching between sources when a source fails or moves out of specification or they can be manual, requiring operator intervention.
if the phase angle between e.m.f and current. then the component of Isin is called wattless current