How many kva need in 30hp motor 3phase?
One horsepower electric is 746 watts, so 30 horsepower is 22.4 KW. You don't specify the power factor or motor efficiency, so I am going to assume a power factor of 0.92 and an efficiency of 0.97, fair values for a 30 horsepower motor. Divide 22.4 KW by 0.92 and then by 0.97 and you get 25.1 KVA. Divide that by three and you get 8.4 KVA per winding. You don't say if the motor is delta or wye connected, so I'm going to assume delta, and multiply by the square root of 3 (1.732) to get 14.5 KVA per phase.
Will the value of joules constant be same if AC were used instead of DC?
Joules measure energy (power x time). If the AC voltage is expressed as rms (root mean square) and not peak, and there are no capacitors or inductors in the circuit, then the joules per second (=power ) will be the same.
Cable schedules provided a tabulated list of all cables with relevant details such as cable number, cable type, size and rating, voltage, number of cores and length of route. Cable schedules are applicable for power cables, control cables, instrumentation cables and industrial data communication cables. In addition to the cable schedules, termination diagrams are provided for use by the electrical installation contractor.
Why does a filament lamp behaves in a way that does not follow ohm's law at higher voltage values?
Actually, everything follows Ohm's Law, you just have to consider dynamic resistance, i.e. the resistance at the precise operating point of the measurement.
A bulb has a positive temperature coefficient, or negative, depending on your point of view. My point of view is that, as temperature increases, the resistance increases, meaning a positive temperature coefficient. An alternate point of view, perhaps the common point of view, is that, as temperature increases, power decreases, meaning a negative temperature coefficient. Pick whichever point of view you want to use.
A typical 60 watt 120 volt bulb might have a 16 ohm cold resistance. (I just measured one.) If it kept that resistance, it would have an operating current by Ohm's law of 7.5 amperes, and a power of 900 watts. However, we know that it runs at 60 watts. Back calculating, that is a current of 0.5 amperes, and a resistance of 240 ohms hot. That a big difference from 16 ohms cold.
Now, that explains temperature coefficient. Lets look at compliance with Ohm's law, and the "theory" that some things do not comply...
Ohm's Law states that voltage is current time resistance. Period. It applies in every case. No exception. The problem is that you have to consider all of the parameters when you take that measurement, and the mistake people make is in assuming the resistance is constant. It is not. Not even for a simple resistor.
If you place two 60 watt bulbs in series across that same 120 volt supply, you will discover that they will run somewhat cooler, and that they have slightly less that 240 ohms resistance, but you can still calculate that resistance and you can still apply ohm's law. In this case, you will find that the power would be slightly more than 15 watts each, not the exactly 15 watts that you would expect based on constant resistance.
On a side note, reinforcing this concept, lets look at the forward bias characteristics of an ordinary silicon diode. This is a point of much contention, but I stand my ground on this...
As you increase the current through the diode, the voltage increases slightly. If it were a perfect diode, the voltage would not increase. If it were a resistor, it would track very close to Ohm's Law. Since it is a diode, it is somewhere in between. Does it obey Ohm's Law? Yes, it does. You simply pick a point, measure the conditions, and you can find the equivalent resistance of the diode at the point of current, and you will find that Ohm's Law will tell you what the voltage should be.
The same thing applies for AC circuits with inductive and capacitive reactance. Now we start talking about impedance and phase angle but, guess what, Ohm's law still applies - you just have to take everything into account.
AnswerIn fact, not everything follows Ohm's Law. An incandescent lamp's filament (tungsten) is an example of a material that does not follow the law. This is because the current flowing through the filament is not proportional to the voltage applied to it. For a material to obey Ohm's Law, there mustbe a linear relationship between current and voltage.
In fact, Ohm's Law makes no mention of resistance. It merely states that 'the current flowing in a circuit is directly proportional to the applied voltage, provided external conditions, such as temperature, remains constant'. No mention of resistance; full stop.
The so-called 'Ohm's Law equation' only represents Ohm's Law when the resistance is a constant. Under all other conditions, the equation simply indicates what the resistance happens to be for specific values of voltage and current -it does not confirm Ohm's Law is being followed.
How is positive lead on an electrolytic capacitor identified?
Normally all electrolytic capacitors negative lead is marked on the side and if the plastic cover came off and it is new the long lead is the positive.
Why is it assumed that during open circuit all the losses are core losses?
Since this is an open circuit test, there is no load attached, thus all losses must be internal to the transformer.
Why is the frequency of a synchronous generator locked into its rate of shaft rotation?
By definition a synchronous generator must be synchronous. If it is not "locked in" it is not a synchronous generator, but an induction machine.
How much output voltage is there if input voltage from a transformer is 32v?
It depends on the turns ratio of the transformer.
What is the current of a circuit that has two 5-ohm resistors and a 12 V battery?
If the two 5 ohm resistors were in series, then the current would be 1.2 amperes. If they were in parallel, then the current would be 4.8 amperes.
Ohm's Law: Current = Voltage divided by Resistance
RSeries = Summation1toN RN
RPARALLEL = 1 / Summation1toN (1 / RN)
Should a star-delta motor be supplied wye or delta power?
A star-delta motor should be supplied star-delta.
Wye is simply another name for star. Star-delta motors use a star or wye configuration to start, and a delta configuration to run. This reduces the voltage on the windings during the high current starting time.
How do NPN bipolar junction transistors turn on and off?
In order to bias a bipolar junction transistor on, you need to forward bias the base-emitter junction at the same time you forward bias the collector-emitter junction, and the ratio of collector current over base current must be somewhat less than hFe, the transistor's gain. This is known as saturated, or non-linear mode, operation. In practice, we drive the base much harder than the calculated required current, so as to minimize dependency on varying hFe's for various transistors.
Turning the transistor off is a simple matter of eliminating the base current.
In the case of the NPN transistor, the base and collector would need to be more positive than the emitter. In the case of the PNP, they would need to be more negative.
How many amp does a 40 hp motor draw at 440 volts?
At 440 volts, a 40 hp motor pulls about 68 amperes. Well, sort of...
The definition of a horsepower for an electric motor is 746 watts. Multiply 746 by 40, and divide by 440, and you do get 68 amperes.
1hp=746W
hence, 40hp=29840W
given that the motor draws 440volts
but current = power/voltage.
therefore, current=29840/440 = 67.81818182 amps.
The complexity, however, is that a motor is an inductive load and it has reactance. This reactance will change the phase angle between voltage and current, causing current to lag voltage by some amount. Power factor is a measure of the ratio of apparent power to true power, and is essentially the cosine of the phase angle between voltage and current. This power factor will make the true power be higher than the apparent power, but horsepower is based on apparent power.
Bottom line is that the amperes in this case will be dependent on the power factor, perhaps about 75 amperes, maybe.
Also, such a motor is bound to be a three phase motor. The amperes will be spread out among the three phases so, for 68 amperes, it would be about 23 amperes per phase, and for 75 amperes, it would be about 25 amperes per phase.
In terms of power factor, it might be closer to unity than anticipated, if the motor has power factor correction capacitors installed.
Keep in mind that starting current will be much higher than running current. Also note that large motors of this type would typically be started in wye configuration, so as to present lower voltage across the windings, and then run in delta configuration, for full power operation.
I'm going to stick with about 25 amperes per phase, full power run mode, unless someone else has something to add, of course.
CommentAn added complication is that '40 hp' refers to the output power of the motor. Unless you know the efficiency, you cannot work out the input power. Incidentally, 68 A single phase doesn't work out at 25 A per line for a 3-phase motor!!!!! It works out a little over 39 Aper line, because P = (root 3) x U x I x power factor!
Draw and explain the operation of fault voltage ELCB and residual current device?
ELCB means Earth Leakage Circuit Breaker -- it is used to trip the Circuit breaker if any leakage fault occured means
Can capacitor store charge from ac source?
Yes. A capacitor stores charge from any source, including AC.
The difference between DC and AC, however, is that the capacitor will be constantly changing in charge, in step with the AC. Due to the nature of the capacitor, the current through the capacitor will lead the voltage by some amount, depending on capacitance and resistance. {In the ideal case of a perfect capacitor, conductors, and AC power source, the current will lead the voltage by 90 degrees phase angle.}
This is called capacitive reactance.
Another way for a capacitor to store charge from an AC source, of course, is to place a rectifier diode in front of the capacitor. This, then, becomes an AC to DC converter.
What is the difference between a seperately excited DC generator and DC shunt generator?
The difference between a separately excited DC generator and a Shunt DC generator is that for a separately excited Dc generator , the excitation field winding is supplied by an external source different from that supplying the armature while for shunt generator, the excitation field windind is connected in series with the armature and supplied by a single source.
Can DC series motor work on ac and DC and why?
A dc series motor can work on dc and ac because dc motors are totally reversible.
How tertiary winding of power transformer acts as stabilizing winding?
in star-star neutral transformer at unbalanced load condition zerosequnce current will be flows in secondary side but this current can not be balanced by primary side because its not having neutral to circulate zerosequence current.due to this unbalance voltage will appeared in primary side but the tertiary delta winding allows circulate the zerosequence current so the primary voltage will get stabilized.
The current level that results in your brain's commands being swamped out; I've heard this called the "let go" threshold as well. If this amount of current is flowing through your hand, you won't be able to let go of whatever it is you were holding.
How do you find the peak value of 110 volts RMS?
The peak of a waveform that is purely sinusoidal (no DC offset) will be RMS * sqrt(2). This is the peak to neutral value. If you are looking for peak to peak, multiply by 2.
An 'a.c. cable' is an electrical cable designed to work with alternating current, rather than with direct current (d.c.). There are a number of important differences, one of which is the level of insulation necessary. For example an d.c. cable designed to operate at 100 V would not be suitable for operating at 100 V a.c., because all quoted values of a.c. voltage are root mean square (rms) values -which means that a 100 V a.c. cable's insulation must be able to withstand a peak value of around 140 V.
What is the hermetically sealed transformer?
Hermatically sealed transformer is a transformer design which has no conservator. Here the dielectric insulating fluid in the transformer tank is completely sealed and is in zero contact to the atmosphere.
This type of transformer is used in applications where the transformer is to be installed in harsh climatic conditions(smoke,pollution,dusty environment,etc) or user prefers low maintenance transformer. The design avoids air in the transformer tank therby avoiding sludging and oxidation of the dielectric fluid. Hence it would be safe to say that these transformers need no maintenance of the dielectric insulatating fluid(usually Oil).
Normally these type of transformers are accommodated by devices that measure heat related volume variations.
Gas cushion is used to compensate the volume variation due to heat. Normally the gas is nitrogen. This gas is thermally uncoupled from the dielectric liquid.
A constant KVA load is an electrical load which has a constant apparent power consumption regardless of small changes in voltage. Constant KVA loads in industry are typically electric motor loads such as induction motors.
The interesting thing about an induction motor and why it is called a constant KVA load is, for a constant level of torque output of the motor, if the terminal voltage decreases by say 5% the motor current will actually increase by about 5%. Note that this constant KVA effect will only occure withing an narrow range of voltage deviation.
This is the opposite of a static (constant Z) load which if the voltage decreases the current decreases.
What types of complications occur with peritoneovenous shunt insertion?
Complications following peritoneovenous shunt insertion are common and include infection, leakage of ascitic fluid, accumulation of abnormally large amounts of fluid in the intercellular tissue.