What is full rated output of dc motor?

It's the maximum mechanical power (either in horsepower or kilowatts) that the motor can deliver without overheating or overloading.

You need to look at the nameplate (if it has one), or get the manufacturer's specs.

It's difficult to know what the output is otherwise.

What happen if the alternator is driven by a motor to generate electric power did it is cost effective?

Alternators are not only driven by turbines, they can be alternator can be driven by any prime mover -including 'motors' if necessary.

What is the most suitable method of starting a 10hp motor with reduced inrush starting current?

The most suitable method for starting a 10hp motor with reduced inrush starting current is using a soft starter. A soft starter gradually increases the voltage supplied to the motor, allowing it to ramp up to full speed smoothly, thereby minimizing the initial surge of current. This method helps reduce mechanical stress on the motor and connected equipment, improving reliability and longevity. Additionally, it can enhance energy efficiency during startup.

Is instead of neutral wire can you ground it by putting the wire in to earth if yes then why is extra wire used for neutral by eleminating netrual wire cost of transmission can be reduced?

Transmission lines do not use a neutral conductor, so your question isn't actually relevant.

Neutral wires are only necessary where imbalance may be large, and under some conditions current may be flowing in the neutral. Under these conditions a low impedance path (the neutral wire) is more desireable than a high impedance path (the ground). In many overhead transmission lines, a fourth or fifth wire are placed above the current carrying conductors; these are shield wires (not neutral wires) and are used to minimize outages on the line due to lightning (the lightning will strike these instead of the phase wires, these will flash over to the structures and the energy will be shorted to ground without the line having to be removed from service). When you're dealing with things that cost ~$100,000 - 2M/mile, it may be worth the added expense of a shield wire to keep it in service as much as possible.

What is the different of induction transformer and automatic transformer?

Neither of these terms is normally applied to a transformer. You may be thinking of a 'mutual tranformer' and an 'autotransformer'. If so, then a 'mutual transformer' is a transformer which has electrically-isolated primary and secondary windings, whereas an 'autotranformer' (the term, 'auto', is misleading and has nothing to do with the transformer being 'automatic'!) has a common and series winding, meaning that the primary and secondary sides are electrically connected to each other.

How much is skewing angle in three phase induction motor?

the skew angle varies from 0 degrees,

depending on how much torque you want at near synchronous speed and how smoothly you want to transition with varying loads

most motors all the shorting bars are parallel to shaft.

skew is more often for lower current starting in motors that will turn on an off a lot

Does an electrical panel get bonded after a step down transformer?

Yes, both to provide a new neutral-bond connection and to equalize potential between various bonds.

Is CT use high or low voltage and if it depends on application or not?

A current transformer (CT) is used to reduce a load current to a value that can be read by conventional instruments such as ammeters and wattmeters; it also enables the instruments to be located remotely. In the case of high-voltage circuits, a CT also electrically-isolates its burden (secondary load) from the primary circuit.

Why do you do polarity test of transformers?

Yes, transformers have polarity.

ADDED. They do in the sense of Live and Neutral or earth-tapping arrangement in a mains wiring system, but otherwise they are not considered to do so because they handle only alternating, not direct, current. So their voltage and magnetic polarities alternate, rather than staying constant.

How do you calculate the feeder size for two or more three phase air condition?

Feeder sizes are based on the amperage of the connected load. Once that is found there are tables in the electrical code book that state what the wire size is for that particular amperage.

How In self excited ac generators the coil gets the excitation voltage from the voltage generated in it?

rectifying the ac to dc and supplying it to armature coils through slip rings and controlling the supplied ampere and voltage(dc),to acheive the desired magnetic feild as per the load demand.

ghaleb

What happened when Distribution Ttransformer neutral earthing failed?

there is a chance of reverse flow of currents in fases so distribution transformer neutral earthing is compulsory

and wr in the case of transmission there is no chance of reverse current flowing because reverse currents flow only from load side

hope ui get me by sandeepraj patnala

Answer

The potential of the line and neutral conductors, with respect to earth, can shift. No reason why the currents should reverse! And removing the earth connection puts the secondary side at risk, in the event of an interwinding fault -i.e. a fault between the h.v. and l.v. side of the transformer.

What is multiple class CT?

a ct is a current transformer

the primary is one turn

this can be a hole you pass a wire thru the laminations

the wire you pass thru the hole can be 300v 600volt or 13200Volt insulation

the core is bolted to the enclosure

clamp on ammeter Amprobe are portable multi class current transformers with meters right on the side

When the current will be short and open circuited?

Open circuit has no current, so does that mean any resistor in series with it, has no current ,so it can be ignored for analysis( v=ir so 0 current means 0 V) for finding lets say the Thevenin equivalent.?

Now for Short circuit, do we ignore a resistor in series with the short, because current will take path of least resistance and ignore that resistor?

Also can short circuit have voltage through it ?

Why is si diode showing 0.7V difference in practical case?

has to do with energy levels in the atomic shells

Geranium is about .2V

Cu CuO2 diodes are used in analog meters they dont have a voltage drop

but are less efficient 75% or so ratio forward to reverse so on a line powered analog meter the low volt scale is a bit different from the others

digital meters gotta have external power anyway so so uses a diode backed with an op amp (hiQuality rectifier)

Why no volt coil is made of thin wire in starter?

because of high voltage

Answer.

The purpose of a no-volt coil is to cut off the power supply from the motor if the voltage supply drops to below a safe pre-determined value.

So, alot of thin wires so that a strong magnetic flux is produced which will keep its armature attracted to the Iron point.

When replacing 2 start capacitors 1 run capacitor and a sinpact switch in the same motor is there a certain order to connect the wires. I have the diagram does it matter which connection first?

Since you have the drawing it would be good if you connect the capacitors according to the drawings. I am saying this since you might end up swaping the start and run capacitors although the run capacitor is usually smaller then the start. However this swapping can be advantageous since it mean slightly increased running talk for the motor.

What are the causes for the field failure in a dc shunt motor and how to troubleshot?

the field winding is just a single magnet

a single pole motor has two usually in series

to start the motor full voltage is put on the field

ok failure modes almost always insulation problems

water, metal chips short to ground

an overloaded motor can induce a reverse polarity in the field causing higher current or voltage (extreme conditions) this also reverses the tempory magnet in all the metal parts and can burn out the winding

to troubleshoot isolate the field put on an ohm meter check the resistance

nameplate will tell the current so 250V 1 a is 250 Ohms

if this in anywhere close there is probably an insulation failure

so find a megohmmeter sufficient to test the insulation

(minimum for 250v 2*250V +1000V or 1500V megger)

100s of megohms is probably safe and with the 1500v it will see any air gaps or pinholes in insulation.

dc is very unforgiving with arcing

if an arc gets started it wont stop until fuses blow

even enclosed motors have brushes and the carbon dust will get on the field windings so they should be cleaned OFTEN.

How a 1N4007 diode become a 1000V diode and 1N4005 become a 600V diode?

naming convention

as for manufacturing

for higher voltage thicker diffusion layer

after manufacture can test them to see which group they fall in

sometimes we get lucky and the whole batch is those 1000v diodes

but you dont want to waste the time in the diffusion oven if you only have 5v costumers